| Attribute | Value |
|---|---|
| Product Category: | |
| Manufacturer: | TE Connectivity |
| Manufacturer Part Number: | TE Connectivity 9-1393211-3 |
| Amperage: | 30 A |
| Mount Type: | Panel Mount |
| Contact Material: | Silver Cadmium Oxide (AgCdO) |
| Number of Poles: | 2 |
| Coil Resistance: | 86 Ω |
| Coil Current: | .142 A |
| Coil Voltage: | 12 VDC |
| Output Type: | AC |
| Maximum Output Voltage: | 600 V |
| Maximum Switching Voltage: | 600 VAC |
| Contact Voltage: | 277 VAC |
| Operating Temperature Range: | -55 - 85 °C, -67 - 185 °F |
| Contact Arrangement: | 2 Form C, DPDT |
| Input Voltage: | 0 - 12 VDC |
| SKU: | AMP9-1393211-3 |
9-1393211-3
Specifications
Detailed Description
Introducing the T92S11D22-12 power relay, a reliable and high-performance solution for your switching needs. With a compact panel mount design, this relay features two poles and DPDT contact arrangement, offering versatile functionality. Rated for 30A at 277VAC, it ensures robust performance in demanding applications. The silver cadmium oxide contacts guarantee longevity and reliability, even in high-power environments. Operating at temperatures ranging from -55 to 85°C, this relay is suitable for a wide range of industrial and HVAC systems. With RoHS compliance and in-stock availability, the T92S11D22-12 is the perfect choice for your relay needs.
Frequently Bought Together
| Product | Part # | Description | Stock |
|---|---|---|---|
| TE Connectivity 770678-1 | SEAL PLUG, AMPSEAL | ![]() |
Product Change Notice
| Effective Date | Description of Change | Download | |||
|---|---|---|---|---|---|
| 09/30/2026 | PCN-26-290912 - Agency Approvals. The marking contents change only from 181G to E214025 , others keep unchanged. | Download | |||
| 09/15/2026 | PCN-26-287891 - Product Change. please be aware of an upcoming change to the listed T92 part numbers. To align with the latest requirements of the UL certification body. TE will make corresponding changes to the marking on the product. Please also note that our UL certificate number has been changed to E214025. There is no impact on the product performance. | Download | |||
| 09/08/2026 | PCN-26-290130-C - PCN Cancellation. This PCN is being withdrawn for internal process correction purposes. A revised PCN will be issued with the same change scope and original effectivity date. | Download | |||