324061
TERMINAL,SOLIS R 8 8
The 324061, a high-performance ring tongue terminal designed for the efficient and secure connection of #8 and M4 stud sizes. With an offset orientation and a durable closed barrel construction, this terminal ensures reliable performance even in the most demanding environments, with an operating temperature range of 170°C (338°F). Suitable for 8 AWG wires ranging from 13100 to 20800 CMA (6.64 to 10.5 mm²), this terminal is perfect for a wide range of industrial applications. RoHS compliant and in stock at IMA, the 324061 is a top choice for professionals seeking quality and reliability in their electrical connections.
Product Category: | |
Manufacturer: | TE Connectivity |
Manufacturer Part Number: | TE Connectivity 324061 |
Connector Type: | Ring Tongue |
Stud Size: | #8, M4 |
Orientation: | Offset |
Operating Temperature Range: | 170 °C, 338 °F |
Wire Size: | 13100 - 20800 CMA, 6.64 - 10.5 mm², 8 AWG |
Barrel Type: | Closed |
Insulated: | No |
Product: | Rings & Spades |
Terminal Angle: | Straight |
SKU: | AMP324061 |
Plating Material: | Copper / Tin |
Inspection Slot: | No |
Weight per Piece: | 2.99 g |
Number of Holes: | 1 |
Military Part Class: | Class II |
Overall Length: | 24.1 mm / .9488 in |
Stud Diameter: | 4.34 mm / .171 in |
Tongue Thickness: | .79 mm / .031 in |
Barrel Inside Diameter: | 4.369 mm / .172 in |
Government Qualified: | Yes |
Wire Insulation Support: | Without |
Heavy Duty: | No |
Wire/Cable Type: | Regular Wire |
Sealable: | No |
Shape Description: | RING-049 |
Support Style: | Non - Insulation Support |
Part Alias: | CN5237-000,AMP-0-0324061-0,45-0132 |
Environmental Initiative Details
Environmental Initiative: | RoHS |
---|---|
Compliant: | Unknown |
Date of this Information: | Unknown |
Notes: |
Product Change Notice
Effective Date | Description of Change | Download |
---|---|---|
06/24/2022 | P-22-022863 - New specification. TE has removed all Class 2 MIL-SPEC references from product labels and literature for the products listed in this PCN( affected products ).Any affected products shipped on or after April 13th,2022 must not be used for applications that specifically require NAVAIR Class 2 qualified product until further notice.The affected products still meet the performance specifications of AS7928 and can continue to be used in commercial applications that do not require NAVAIR Class 2 qualified product.TE Class 1 products remain active on the NAVAIR Class 1 QPL and can continue being used for applications requiring NAVAIR Class 1 qualified product.TE AS7928 Class 2 products were removed from QPL-7928(Class 2) Supplemental Information Sheets for Qualified Products Lists(QPLs), effective April 13, 2022.Since Class 2 parts must be ordered by the manufacturer s standard part number, TE standard package labels indicated both the commercial(standard TE) part number and the applicable MIL-SPEC reference(s). | Download |
06/04/2022 | P-22-022863 - New specification. TE has removed all Class 2 MIL-SPEC references from product labels and literature for the products listed in this PCN( affected products ).Any affected products shipped on or after April 13th,2022 must not be used for applications that specifically require NAVAIR Class 2 qualified product until further notice.The affected products still meet the performance specifications of AS7928 and can continue to be used in commercial applications that do not require NAVAIR Class 2 qualified product.TE Class 1 products remain active on the NAVAIR Class 1 QPL and can continue being used for applications requiring NAVAIR Class 1 qualified product.TE AS7928 Class 2 products were removed from QPL-7928(Class 2) Supplemental Information Sheets for Qualified Products Lists(QPLs), effective April 13, 2022.Since Class 2 parts must be ordered by the manufacturer s standard part number, TE standard package labels indicated both the commercial(standard TE) part number and the applicable MIL-SPEC reference(s). | Download |
05/07/2013 | Document clarification. | Download |