The 1473244-1 is a high-quality MQS REC 81P ASSY connector designed for automotive applications. Featuring housing for female terminals with four rows and a pitch of 2.54mm, this connector ensures reliable signal transmission in your vehicle system. With a voltage rating of 12V DC and operating temperature range of -40 to 120°C, it's suitable for a wide range of automotive functions. The UL 94-HB flammability standard and RoHS compliance guarantee safety and environmental responsibility. Sealable for added protection, this connector is 3.008 inches long, 1.22 inches high, and 1.472 inches wide, with a 90° cable exit angle. Its black body color and terminal position assurance make it a durable and secure choice for your automotive connectivity needs.
AVAILABILITY
Immediate Shipment:NA
Stock Location:In Stock
Factory Stock:Call for Stock
Factory Lead:
Unit Of Measure:
Minimum/Multiple:1/1
Pricing
CALL: 800.422.3911
Invalid quantity value
Product Category:
Manufacturer:TE Connectivity
Manufacturer Part Number:TE Connectivity 1473244-1
Series:MQS
Gender:Housing for female terminals
Number of Rows:3, 4
Pitch:.114 in, .1 in, .228 in, 2.54 mm, 2.9 mm, .311 in, 5.8 mm, 7.9 mm
Voltage:12 V DC
Row Spacing:.173 in, 4.4 mm
Polarization:Yes
Number of Positions:81
GPL:N02
Operating Temperature Range:-40 - 120 °C, -40 - 248 °F
Circuit Application:Signal
Sealable:Yes
GPL Description:Automotive
Product Code:M107
Connector System:Wire to Board, Wire-to-Device
Length:3.008 in
Cable Exit Angle:90°
Height:1.22 in, 31 mm
Width:1.472 in, 37.4 mm
Mating Tab Width:.025 in, .11 in, 2.8 mm, .63 mm
Nominal Voltage Architecture:12 V
Body Color:Black
Serviceable:Yes
Mounting Feature:Without
Terminal Position Assurance:Yes
Connector Position Assurance Capable:No
Hybrid Connector :Yes
Material Flammability Standard:UL 94-HB
Part Aliases:1473244-1
SKU:AMP1473244-1

Environmental Initiative Details

Environmental Initiative:RoHS
Compliant:Unknown
Date of this Information:Unknown
Notes:

Product Change Notice

Effective DateDescription of ChangeDownload
02/20/2024P-23-025380 - MOQ & DU Change. To inform you about a change in delivery unit & minimum order quantity (MOQ) impacting PNs listed below in this PCN. Change was already communicated via P-23-024531 but new PCN informs about postponed activation date: As of February 20, 2024 we will increase the delivery unit & the min. order quantity according to attached file. The order quantity should therefore be not less than the MOQ and should be dividable through the MOQ. Dimensions and material of product and shipping box will stay the same. The change has no impact to form-fit-function. TE Change process follows a strict procedure, which fully maintains quality and ability to supply. The product in scope of this PCN is TE general sales / catalogue product, therefore TE reserves the right to determine delivery unit & MOQ. No PPAP will be submitted for this PCN. It is kindly requested to adjust order quantities before the activation on February 20, 2024 to avoid blocked orders.
Download
02/20/2024P-23-025381 - MOQ & DU Change. To inform you about a change in delivery unit & minimum order quantity (MOQ) impacting PNs listed below in this PCN. Change was already communicated via P-23-024531 but new PCN informs about postponed activation date: As of February 20, 2024 we will increase the delivery unit & the min. order quantity according to attached file. The order quantity should therefore be not less than the MOQ and should be dividable through the MOQ. Dimensions and material of product and shipping box will stay the same. The change has no impact to form-fit-function. TE Change process follows a strict procedure, which fully maintains quality and ability to supply. The product in scope of this PCN is TE general sales / catalogue product, therefore TE reserves the right to determine delivery unit & MOQ. No PPAP will be submitted for this PCN. It is kindly requested to adjust order quantities before the activation on February 20, 2024 to avoid blocked orders.
Download
07/20/2023P-23-024531 - Change to DU & MOQ. change in delivery unit & minimum order quantity (MOQ) impacting PNs listed below in this PCN. As of July 20, 2023 we will increase the delivery unit & the minimum order quantity according to attached file. The order quantity should therefore be not less than the MOQ and should be dividable through the MOQ. Dimensions and material of product and shipping box will stay the same. The change has no impact to form-fit-function. TE Change process follows a strict procedure, which fully maintains quality and ability to supply. No PPAP will be submitted for this PCN.
Download
05/01/2023P-23-024232 - Raw material change. Change the raw material supplier. The raw material grade is the same and there is no impact production function and performance.
Download
11/27/2017P-17-014883 - Manufacturing Location Change. Mold process line manufactured in TE Korea move from ATS to Genesis.Download
11/27/2017P-17-014884 - Manufacturing Location Change. Mold process line manufactured in TE Korea move from ATS to Genesis.Download
11/27/2017P-17-014885 - Manufacturing Location Change. Mold process line manufactured in TE Korea move from ATS to Genesis.Download
11/27/2017P-17-014887 - Manufacturing Location Change. Mold process line manufactured in TE Korea move from ATS to Genesis.Download
11/27/2017P-17-014888 - Manufacturing Location Change. Mold process line manufactured in TE Korea move from ATS to Genesis.Download
11/27/2017P-17-014889 - Manufacturing Location Change. Mold process line manufactured in TE Korea move from ATS to Genesis.Download
11/27/2017P-17-014890 - Manufacturing Location Change. Mold process line manufactured in TE Korea move from ATS to Genesis.Download
11/27/2017P-17-014890 - Manufacturing Location. Mold process line boxs manufactured in TE Korea move from ATS to Genesis. (Distance between two plants is about 1.5Km).Download
11/27/2017P-17-014891 - Manufacturing Location Change. Mold process line manufactured in TE Korea move from ATS to Genesis.Download